Six feet of ceiling, inside one resort.
Every ballroom here is big enough for a plenary. Published heights run from 12 feet to 20, and one resort holds six of that spread.
| Ballroom | Published height | Published floor | Property |
|---|---|---|---|
| Las Olas Ballroom | 20 ft | 10,829 sq ft · 119 × 91 ft | The Westin Fort Lauderdale Beach Resort |
| Cornerstone Ballroom | 17 ft | 5,400 sq ft · 100 × 54 ft | Renaissance Fort Lauderdale West |
| Grand Floridian Ballroom | 14 ft | 11,704 sq ft · 152 × 77 ft | Fort Lauderdale Marriott Coral Springs |
| Atlantic Ballroom | 14 ft | 9,191 sq ft · 101 × 91 ft | The Westin Fort Lauderdale Beach Resort |
| Seabreeze Ballroom | 14 ft | 5,852 sq ft · 154 × 38 ft | Marriott Fort Lauderdale Airport |
| Florida Ballroom | 14 ft | 5,049 sq ft · 99 × 51 ft | The Westin Fort Lauderdale |
| Grand Cypress Ballroom | 12 ft | 5,082 sq ft · 66 × 77 ft | Fort Lauderdale Marriott North |
Read the first column against the fourth. The Westin Fort Lauderdale Beach Resort publishes two ballrooms either of which will hold a general session, and six feet of height between them: the Las Olas at 20 feet, the Atlantic at 14. That six feet carries most of the video and lighting decision. Under a 14-foot ceiling the bottom of a flown screen still has to sit above the heads in front of it, the top of the image then runs out of ceiling, and so the screen grows wider rather than taller and the content gets laid out for a letterbox. At 20 feet the same seat count takes a taller image, a header above it, and a front lighting position hung far enough forward to light a presenter’s face rather than the top of their head. The 12-foot ballroom on this chart is the one where the rig comes off the floor instead: ground support under the screen, lighting on floor bases up the side walls, and a camera position low enough to shoot under all of it. One limit on every figure in this table, and it is the property’s own. The column these come from is headed Dimensions (LxWxH) rather than ceiling height, and each of these charts carries the line that all room sizes are approximate. A published height tells us which builds are worth drawing. The site survey settles what hangs.
Sources — each property’s own published event-space chart
- The Westin Fort Lauderdale Beach Resort — event spaces, with the Dimensions (LxWxH) column for the Las Olas and Atlantic ballrooms
- Renaissance Fort Lauderdale West Hotel — event spaces, with the same column for the Cornerstone Ballroom
- Fort Lauderdale Marriott Coral Springs Hotel & Convention Center — event spaces, Grand Floridian Ballroom
- Marriott Fort Lauderdale Airport — event spaces, Seabreeze Ballroom
- The Westin Fort Lauderdale — event spaces, Florida Ballroom
- Fort Lauderdale Marriott North — event spaces, Grand Cypress Ballroom
Two ballrooms, almost the same width, thirty-nine feet apart in depth.
Floor area tells you how many chairs fit. The proportion tells you where they sit, and that is what the screen has to cover.
The wide, shallow ballroom
The Seabreeze Ballroom at Marriott Fort Lauderdale Airport is published at 5,852 square feet and 154 by 38 feet. At 38 feet deep the rows run out well before the seat count does, so the audience spreads sideways instead of back. The seats at either end then look across the image rather than at it, and that angle is what decides whether one surface serves the space or the build needs a second one with a camera cut feeding it.
The deep ballroom
The Grand Floridian Ballroom at Fort Lauderdale Marriott Coral Springs is published at 11,704 square feet and 152 by 77 feet — two feet narrower than the Seabreeze and twice as deep. Same width, and the problem moves to the back of the house: distance to the last row sets how tall the image has to be, and it sets the point past which a face on camera is carrying the presenter rather than the presenter carrying the space.
What settles it
The seating plan, which is why we ask for it before anything is specified. Banquet rounds push the last row further back than theater rows at the same headcount, so two events with the same guest list in the same ballroom can need different image heights. The plan is also what shows where a front-of-house position can sit without taking out saleable seats, and in a shallow ballroom that position competes with the audience for the only depth there is.
Two convention centers in this market, opposite rules on smoke.
A lighting look that reads only because the air is hazed is one the building can refuse. Both of these publish their position.
Broward County: allowed, with a fire watch
The Greater Fort Lauderdale/Broward County Convention Center puts it in a single line in its fire code regulations: “A Fire watch is mandatory when smoke and/or hazardous machines are used inside.” Its smoking policy adds the reason plainly — “Fire Alarms may go off due to smoke inside the building.” In that building haze is a notification and staffing item rather than a lighting one, and the same guide names who decides: “The decision of the Fire Marshal of the City of Fort Lauderdale is final.”
Palm Beach County: not at all
The Palm Beach County Convention Center takes the other position, under decorations in its facility guide: “Helium balloons, fog machines, and smoke effects are not permitted within the facility.” Its fire safety section is as short on effects: “No pyrotechnics are allowed in the PBCCC at any time.” A plot drawn around atmosphere does not travel from one of these buildings to the other.
Where that lands in the schedule
In the venue survey, ahead of the lighting plot rather than after it. A beam that exists only because the air is loaded has to be replaced by something else doing the same job — surface, edge and contrast built into the scenic, and more work from the screen. That is a design change, so it wants to happen while the design is still on paper. Both figures above are the buildings’ own published wording, and a guide gets reissued between contract years: confirm the rule with the venue for the event date before a look depends on it.
The five answers a plenary turns on.
Send these and a scope comes back with the hang, the screen and the crew in it.
- The property and the ballroom by name
Not the city and not the headcount alone. Two ballrooms in one resort can be six feet apart in published height, and the name is what tells us which build is even drawable. Where the property publishes no height, it goes on the survey list instead of being assumed.
- The seating plan, or the headcount and the style
Rounds or theater rows, and whether there is a dance floor or a buffet taking depth out of the space. That plan sets the distance to the last row, which sets image height, and it sets where the mix position can sit.
- Whether anything may touch the ceiling
Whether the property has certified rigging points, how many, and rated for what. That answer decides a flown build against a ground-supported one before it decides a single item of gear, and it is held by the chief engineer rather than printed on the capacity chart.
- The run of show, even in draft
A keynote with a video package, an awards segment with walk-ons and a panel with four chairs are three different lighting and audio builds in the same ballroom. A draft running order moves a scope further than a finished one arriving late.
- Whether the look needs atmosphere
Ask it early, because the answer is the building’s rather than ours. One convention center in this market requires a fire watch for it and another prohibits the machines outright, and a hotel ballroom sits under its own house rules and the local fire marshal.
What the plenary sits inside, and what the estimate turns on.
A general session is one part of a program. The gear list and the estimate are separate questions.
Send the ballroom and the headcount. We will scope the rest.
Email the date, the property and the ballroom, and a scope comes back with the hang and the screen in it. Quotes within 24 hours.